Should I keep a 12V buffer battery after installing a 48V inverter system?
Moving the inverter to 48 V does not move the coach. Lights, water pump, furnace fan, slide motors, jacks, awning and the tongue jack all stay 12 V, and something has to feed them. The choice is a 48-to-12 converter running the loads directly, or a converter charging a small 12 V battery that feeds the loads. The right answer comes from the peak current, not the average.
The numbers that decide it
A converter has a hard current ceiling; a battery does not. Victron's manual for the isolated Orion-Tr Smart gives these ratings for the 48 V input models:
| Model | Continuous at 40 °C | 10-second peak | Short-circuit current |
|---|---|---|---|
| 48/12-20 | 20 A | 25 A | 50 A |
| 48/12-30 | 30 A | 40 A | 60 A |
Both derate 3 percent per degree above 40 °C, so in a hot basement bay the continuous figure is lower. Motor loads such as slide-outs, levelling jacks and a powered tongue jack draw far more at start-up and stall than when running. Read the fuse or breaker on each of those circuits: if it is rated above the converter's ten-second figure, a converter alone will sag or shut down mid-travel. With a 12 V battery in circuit, the battery supplies the surge and the converter refills it at its 20 or 30 A pace. That is the whole case for keeping the buffer.
When to drop the battery
If the 12 V side is lighting, a 3 GPM water pump, the fridge control board, fans and USB outlets, add the nameplate amps up. If simultaneous load stays under about three quarters of the converter's continuous rating and nothing has a motor surge, a plain Orion-Tr 48/12 converter is the simpler install: no second battery to monitor, no second chemistry to charge. Victron's input range on these is 32 to 70 V, so a full 16-cell LiFePO4 pack at 58.4 V is well inside it.
If you keep the battery, use the Smart model
Victron says the plain Orion-Tr is not meant for charging a battery; the Orion-Tr Smart is. Set it to charger mode in VictronConnect with the profile for the buffer battery's chemistry, and it holds that battery full while the loads draw from it. A small 12 V battery is enough; it only has to cover surges, not run the coach overnight.
Wire it per the manual: on the 48 V input a 20 A fuse and 2.5 to 6 mm² cable depending on length; on the 12 V output a 60 A fuse and 6 to 16 mm². The isolated model keeps the 48 V and 12 V negatives separate, which avoids the current-bypass problems a shared negative causes with a shunt or a BMS that switches the negative. Idle cost is small: under 80 mA at the input with no load, and under 1 mA when switched off on the remote terminal, so wire the remote to a switch or the ignition if the rig sits for weeks.
Monitoring two banks
Put a SmartShunt on the 48 V bank negative with the converter on its load side, so the 12 V consumption is counted against the main bank. Its auxiliary input can read the buffer battery's voltage as a starter-battery reading, so one device shows both.
Everything here ships from Upland, California. Send us your 12 V load list and we will tell you whether a converter alone will hold up.
What you need
Want the full walkthrough? Read the complete guide.