Why does my Orion-Tr Smart say input voltage lock-out while the engine is running?
VictronConnect shows two different reasons for a disabled charger, and owners read them as one. "Engine shutdown detected" comes from the start and shutdown voltage logic. "Input voltage lock-out" is a separate floor: in charger mode it defaults to 12.5 V, and the charger will not restart until the input climbs back to 12.8 V. Victron scales both by model, so a 24 V input unit uses double the figures.
Why a D+ or ignition wire does not fix it
Wiring a signal above 7 V to the remote connector's L-pin tells the charger the engine is running and forces charging on, even when the detection logic has decided the engine stopped. That is all it does. The lock-out is defined separately as the minimum input level at which charging is allowed at all; below it, charging stops immediately. Victron's warning about forced charging makes the same point from the other side: with detection switched off, the lock-out is the only limit left. So if the alternator is only producing 12.4 V, the charger stays off with the signal connected.
Two wiring details from the manual matter here. The signal must be referenced to the input (starter) battery, because the isolated model's two sides do not share a negative. And remote option c, where the L-pin is switched to ground, cannot be combined with an engine signal because both use the L-pin. If your vehicle's engine-running output is pulled to ground rather than to 12 V, Victron's answer is a small relay: coil between a fused starter positive and the vehicle terminal, normally-open contact between a fused starter positive and the L-pin. Leave engine shutdown detection switched on in the app; the signal forces charging on, detection still stops it when the engine is off.
Setting the lock-out correctly
The manual gives the rule: the lock-out must sit below the shutdown voltage by at least the voltage lost in the input cable, because when a smart alternator's voltage drops quickly the charger needs time to throttle back. Victron's own example: a 12/12-30 draws about 35 A at the input; through 10 m of 16 mm² cable (5 m each way) at about 11 milliohms that is roughly 385 mV, so with a 13.3 V shutdown level the lock-out should be about 12.9 V or lower. If a Euro 6 vehicle idles below 12.5 V, you may also lower the lock-out, but the manual warns that setting it very low can flatten the starter battery whenever forced charging is enabled.
The fault that looks the same
If the input reads 14 V with the charger off and collapses to around 9 V the instant it starts, the alternator is fine and a connection is not. Loose input terminal, failing fuse, corroded ground or a tired isolator will all read full voltage at no current and crash under 35 A, so the charger cycles on and off. Check every joint on the input side before touching settings.
Euro 6 vehicles
Victron notes that some alternator management systems switch the alternator off entirely during a drive, letting the starter battery fall to its resting voltage of about 12.6 V. Detection then correctly reads "engine off" even though you are moving. Lowering the start and shutdown levels helps on some vehicles; on others only the external engine signal keeps charging going. The Orion XS has the same smart-alternator settings in a higher-current package if you are still choosing hardware.