If your rooftop air conditioner is more than a decade old, struggling to keep up, or rattling like a toolbox on the highway, replacement is usually smarter than repair — and it's a genuinely achievable DIY job. Nearly every RV rooftop AC drops into the same industry-standard 14″ × 14″ roof opening, which means a modern low-profile unit like the Dometic Penguin II 15,000 BTU is a direct swap for most old units.
Here's the full process. Budget a half day, and recruit a second person for the lifting.
Before you start
- Confirm the opening. Measure your existing roof cutout — you're looking for 14″ × 14″. Still unsure whether you need 13,500 or 15,000 BTU? Read our BTU comparison guide.
- Ducted or non-ducted? The Penguin II works both ways. Non-ducted installs need an air distribution box on the ceiling side; ducted rigs reuse the existing ceiling plenum.
- Kill the power. Disconnect shore power and switch off the AC breaker. You'll be working with 120V wiring.
- Check your roof rating. You'll be walking on the roof with a unit that weighs around a hundred pounds — use plywood to spread your weight on thinner roofs.
Step 1: Remove the old unit
- Inside, remove the ceiling assembly (shroud, filters, and the bolts that clamp the unit to the roof). Photograph the wiring connections before you disconnect anything.
- On the roof, cut through any old sealant around the base with a putty knife.
- Lift the old unit off the opening — this is the two-person part — and lower it down carefully.
- Scrape the old gasket residue off the roof around the opening and clean the mounting surface. A clean, flat seating surface is what keeps water out; don't rush it.
Step 2: Set the new Penguin II
- The new unit comes with its roof gasket. Set the Penguin II over the opening and align the gasket with the cutout — the aerodynamic housing points forward.
- From inside, install the mounting bolts through the ceiling frame and tighten them evenly, in a cross pattern, to the torque in the included instructions. This compresses the gasket uniformly. Over-tightening one corner is the #1 cause of both leaks and vibration.
Step 3: Wiring and ceiling assembly
- Reconnect the 120V supply per the wiring diagram in the manual — it matches what you photographed in almost every replacement scenario.
- For non-ducted setups, mount the air distribution box; for ducted, connect the divider and duct openings.
- Install filters and the interior grille.
Step 4: First startup
- Restore the breaker and shore power.
- Run the fan first, then cooling. Compressor startup should settle into a smooth hum — the Penguin II's rib-reinforced base pan and low-profile housing make it noticeably quieter on the road and at the campsite than decade-old units.
- After the first rain (or a hose test), check the ceiling perimeter for any sign of moisture. A properly torqued gasket needs no extra sealant on most installs.
Common mistakes to avoid
- Reusing a crushed gasket from the old unit. Always seat the new one.
- Sealing with self-leveling lap sealant “just in case.” The gasket is the seal; burying the base in sealant makes future service miserable and can trap water.
- Uneven bolt torque — leads to leaks on one side and rattles on the other.
- Ignoring the refrigerant type. The Penguin II runs modern R-410A — a sealed system, nothing to charge or top up on installation.
FAQ
Can one person do this install? The wiring and torque work, yes. The roof lift, no — get help or rent a lift for the unit itself.
Will it work with my existing thermostat? Non-ducted installs use the controls on the air distribution box. Ducted installs vary by rig — check the control kit compatibility in the manual before ordering.
How long does it take? Most first-timers finish in 3–5 hours including cleanup.
Ready to swap? The Dometic Penguin II 15,000 BTU ships free with free 30-day returns — and code RVSAFE10 takes 10% off your order.