What size Renogy charge controller do I need for 400W of solar?
Controller sizing comes down to one calculation: the charge current the array can push into the battery. Divide array watts by battery voltage.
At 12V, 400W divided by 12 is about 33A. Controllers are sold in fixed ratings, so you round up to the next one — 40A. At 24V, the same 400W divides by 24 for roughly 17A, and a 20A controller handles it.
That is why the same array can need a different controller depending on how your bank is wired. It is the battery voltage that sets the current, not the panel voltage.
Why round up rather than match exactly
Two reasons. Panels occasionally exceed their rated output in cold, bright conditions — cell efficiency rises as temperature drops, so a 400W array on a clear winter morning can briefly push past its nameplate. And if you ever add a panel, a controller sized exactly to today's array has to be replaced, while one with headroom absorbs the change.
The Rover Li is sold in 20A, 30A and 40A ratings across one product line, so stepping up a size is a matter of picking a different option rather than a different product.
Check your wire gauge too
The 40A Rover Li accepts conductors up to 8AWG at its terminals. If you are running a long cable from a roof array to a controller mounted inside, size the wire for the run length before you assume the terminal will take it — a gauge that the distance demands may not physically fit, in which case the controller goes closer to the battery and the panel run is made at higher voltage.
If your array is larger
Above roughly 700W on 12V you are past what a 40A controller will take, and the 60A Rover is the next step. The arithmetic does not change: watts divided by battery voltage, then round up.
One setting people miss
The Rover Li detects 12V or 24V systems automatically for non-lithium batteries. If you are charging LiFePO4, set the battery type in the controller yourself rather than trusting the auto-detection — the charge profile for lithium is different from the flooded or AGM default, and getting it wrong means the bank never reaches a full state of charge.