Short answer: Budget about 837Wh, or 65Ah at 12V, for each hour on a warm night. Four warm hours plus a 12V fridge is about 3,900Wh a day and 1,050W of panels to put it back. Eight warm hours is about 7,250Wh and 1,950W of panels, more than an RV roof holds, so solar alone will not carry overnight AC.

Our calculator counts a 13,500 BTU rooftop unit at about 1,400W while the compressor runs, fed through a 92% efficient inverter. The night decides how much of each hour it runs: about 35% in the 70s, 55% in the 80s, 70% in the 90s and above.

Cost of one hour

Night Wh per hour Ah per hour at 12V
Mild, 70s About 533Wh About 42Ah
Warm, 80s About 837Wh About 65Ah
Hot, 90s and up About 1,065Wh About 83Ah

That is roughly 180Wh an hour less than a 15,000 BTU unit on the same warm night.

A full day, AC plus the rest of the rig

Every figure below adds about 550Wh for a 12V fridge, lights, water pump, phones and fans.

AC hours Mild Warm Hot
2 hours 1,616Wh 2,224Wh 2,681Wh
4 hours 2,681Wh 3,898Wh 4,811Wh
6 hours 3,746Wh 5,572Wh 6,942Wh
8 hours 4,811Wh 7,246Wh 9,072Wh

Battery: which system the calculator picks

It needs 2,100W of inverter output for this unit (one and a half times running watts) and enough watt-hours for one day:

  • 2 mild hours: Jackery Explorer 2000 v2. At 2,200W it clears the output bar for a 13,500 BTU unit, which it does not for a 15,000.
  • 2 warm or hot hours, or 4 mild: BLUETTI Apex 300 at 2,764Wh.
  • 4 warm or hot hours, 6 mild, or 8 mild: Apex 300 + B300K at 5,529Wh.
  • 6 warm hours: Comvolt 6000 Pro, 6,016Wh and 2,500W.
  • 6 hot or 8 warm hours: Apex 300 + two B300K, 8,294Wh.
  • 8 hot hours: nothing in the list; the calculator moves you to a built-in bank.

These match rated capacity with no reserve, so pick a step above if the line is close.

On a 12V lithium bank, 8 warm hours is about 566Ah a day. At 85% usable that is a 700Ah bank for one night and 1,350Ah for the calculator's default two days. The AC would draw about 119A from 12V while running, which is why the calculator suggests 24V at this size and pairs it with a MultiPlus 3000-class inverter.

Solar: what it takes to put it back

At five sun hours and 75% harvest, each warm AC hour needs about 220W of panel. The day totals work out to:

  • 2 warm hours: 600W of panels
  • 4 warm hours: 1,050W
  • 8 warm hours: 1,950W

The largest kit in the calculator, the Renogy 800W Essential, makes about 3,000Wh on a five-hour day. After the 550Wh base, that refills about three warm hours of a 13,500 BTU unit. Longer runs need a generator, shore power or driving to make up the rest.

Making it easier to run

A soft starter such as the EasyStart Flex 398 cuts start-up surge, which helps a power station or small generator start the compressor. It does not reduce the hourly watt-hours above. Running the AC in the afternoon while the panels produce, rather than overnight, also takes load off the battery.

Enter your own AC hours, nights and sun in our RV solar and battery calculator to size the full system.

What you need

Want the full walkthrough? Read the complete guide.