Will a Blue Sea m-LVD stop my RV loads from draining the battery?
Short answer: Yes, for up to 65A of 12V loads on one battery. The 7635 cuts the loads when the battery stays below its set point, adjustable from 11.3V to 12.1V (12.1V from the factory). It alarms after 5 minutes and disconnects 5 minutes later. It reconnects only when a charger lifts the battery to 13.0V for 2 minutes or 13.5V for 30 seconds.
Yes, as long as your setup fits its limits. Blue Sea built the m-LVD (7635) for a single 12V battery. It watches the voltage and disconnects the non-essential loads before the battery goes flat.
The numbers, from Blue Sea's instructions
| 7635 | |
|---|---|
| System | 12V DC only. Blue Sea says it is not for 24V |
| Continuous load | 65A (115A for 5 min) |
| Cable to meet rating | 6 AWG, 1/0 AWG max; 1/4"-20 studs |
| Disconnect set point | 11.3, 11.5, 11.7, 11.9 or 12.1V |
| Factory setting | 12.1V |
| Delay | 5 min below the set point, then 5 min of alarm, then disconnect |
| Reconnect | above 13.0V for 2 min, or 13.5V for 30 s |
| Remote switch | included (PN 7928) |
What that means in an RV
- Wire it in the line feeding your non-essential loads, such as a fuse block with the lights, fans, pump and USB chargers. Their combined current has to stay under 65A. Leave the safety devices (CO/LP detector) and anything that must stay on outside the LVD.
- It does not reconnect when the loads switch off. A resting battery won't climb back to 13.0V. Power returns only once a charger, solar or the alternator lifts the voltage. Until then you can press OVERRIDE on the remote for 10 more minutes of power.
- Short dips are ignored. The voltage has to stay below the set point for a full 5 minutes before the alarm starts. A water pump or inverter surge won't trip it.
- Changing the set point: hold OVERRIDE for 10 seconds. The LED flashes the current setting (1 flash = 11.3V up to 5 flashes = 12.1V). Press OFF to lower it in 0.2V steps or OVERRIDE to raise it. Release, and it saves after about 20 seconds.
What it is not
- It is not a charger link. Blue Sea's FAQ says an ACR is the right part for charging a second battery, not the LVD.
- It is not for lithium-specific cutoffs. Blue Sea's pages don't mention lithium. If your house battery is LiFePO4, look up its low-voltage limit in the battery manual before you choose a set point, or ask us.
An optional alarm (up to 250mA) can be wired to the alarm output so you hear the 5-minute warning.
What you need
Have a different question? Tell us your rig and what you're trying to do.