Can the Comvolt AC-DC Power Hub replace my RV's 12V converter?
Partly. An RV converter does two jobs. It powers the 12V loads when you are plugged in, and in most rigs it charges the house battery too. The Comvolt AC-DC Power Hub does the first job well. Comvolt doesn't list it for the second.
What the hub is
Inside is a 1,200W, 80 PLUS Platinum server power supply rated for 1,000W continuous at 12V:
| Spec (Comvolt) | Figure |
|---|---|
| AC input | 100–240V AC, 50/60Hz, IEC C13 inlet; 14A max at 120V |
| DC output | 12V, 1,000W continuous (97.5A max), 1,050W peak on 120V |
| High-current outputs | 1 pair of M8 copper posts and 1 × 50A grey Anderson, in parallel |
| Branch circuits | 6 fused push-in terminals, 30A max each |
| Fuses in the box | ATC/ATO blades, 5 to 30A, 4 of each |
| Efficiency | 94%+ peak |
Where it can stand in for a converter
12V loads on shore power or a generator. Comvolt sizes it for a 12V fridge, a diesel heater, the water pump, lights, fans and a Starlink dish at the same time. If your converter is too small, noisy or dead and the rig runs a lot of 12V gear on hookups, this covers it, with six fused circuits included.
Wiring: Comvolt calls for 4 AWG or heavier on the M8 posts and Anderson outlet, and 18–14 AWG on the branches, sized to each branch's fuse. Fit each branch fuse to its wire, not to the 30A terminal maximum.
Where it can't
Charging the house battery. Comvolt lists the output as a fixed 12V DC supply. It lists no charging stages, no lithium or lead-acid profile and no battery temperature input, and doesn't present it as a battery charger. Don't wire it as the only thing charging a battery bank. Keep a proper charger for that, such as the converter you already have, or Comvolt's wall charger for a Comvolt station.
Mounting outdoors or in a sealed bay. It is rated for an indoor, dry, ventilated spot with 2 in of clearance around the vents. It has a temperature-controlled fan.
Running it from a power station
You can feed it from a station's AC outlet, but on a Comvolt station there is a shorter path. The 2200, 4200 and 6000 Pro already put 12V out of their 120A Anderson port. Running AC out of the station only to turn it back into 12V converts the power twice. For 12V loads from a Comvolt station, use the station's Anderson port with the DC PDU. Use the Power Hub when the source is shore power or a generator.
Not sure how it fits your rig's wiring? Send us a photo of the converter panel. RV Parts Giant, Upland, CA.
What you need
Want the full walkthrough? Read the complete guide.