Can a handheld CO meter like the Klein ET110 replace the CO alarm in my RV?
Two different jobs
| Klein ET110 | Safe-T-Alert 85-741 | |
|---|---|---|
| What it is | Handheld carbon monoxide meter | Fixed CO and propane alarm |
| Reads | Actual CO level, with alarms at 35 ppm (low) and 200 ppm (high) and a short-term exposure limit | Alarms on CO and on propane / LP gas |
| Power | Batteries, included | 12V DC hard-wired to the RV, 108 mA, low-voltage warning |
| Standards on the listing | None stated | UL 2034 RV and UL 1484 RV; meets RVIA/NFPA requirements |
| Where it lives | In its carry pouch, in your hand | On the wall, all the time |
Our CO detector guide sets out what an RV with a propane stove, furnace, water heater or generator needs. It needs a CO detector listed to UL 2034, wired directly to the battery and not through the battery disconnect. A handheld meter in a pouch does not meet that, however good it is. It only alarms while it is switched on and near the gas.
What the ET110 is good for
The meter shows a number, not just an alarm. That is what you want when you are tracking a problem:
- Walking the outside of the rig with the generator running, to see whether exhaust is collecting near a window, vent or the door.
- Checking around the furnace exhaust and a portable heater.
- Confirming the reading after a fixed alarm goes off, once everyone is outside and the rig is aired out. The fixed alarm tells you to leave. The meter helps find the source.
Replacing the fixed alarm
If the alarm on your wall is old, or is propane-only, the Safe-T-Alert 85-741 is MTI's universal replacement. Its trim ring covers old screw holes and fits the cutout of an older detector. It is 7 x 4 x 1 in with the ring. MTI says its universal bracket replaces almost all alarms on the market, including Safe-T-Alert, Atwood, CCI and Dometic. It comes in white (85-741-WT-TR) or black (85-741-BL-TR).
It runs on the RV's 12V supply. Wire it to the battery, not through the battery disconnect, as the guide says. That way switching off the house loads never switches off the alarm.
What you need
Want the full walkthrough? Read the complete guide.