How much battery do I need to run a 15,000 BTU RV air conditioner?

Answered by RV Parts Giant · Upland, CA · November 2, 2026

Short answer: Plan on about 1,016Wh, or 79Ah at 12V, for every hour on a warm night. Eight warm hours plus a 12V fridge comes to about 8,700Wh, which is more than an Apex 300 with two B300K batteries holds. Mild nights need about a third less. Four warm hours fits a 5,529Wh system.

Our calculator counts a 15,000 BTU rooftop unit at about 1,700W while the compressor runs, through a 92% efficient inverter. How much of the time it runs depends on the night: about 35% in the 70s, 55% in the 80s and 70% in the 90s and above.

What one hour costs

Night Wh per hour Ah per hour at 12V
Mild, 70s About 647Wh About 51Ah
Warm, 80s About 1,016Wh About 79Ah
Hot, 90s and up About 1,293Wh About 101Ah

Total daily use

Each figure includes about 550Wh for the rest of a typical rig: 12V fridge, lights, pump, phones and fans.

AC hours Mild Warm Hot
2 hours 1,844Wh 2,583Wh 3,137Wh
4 hours 3,137Wh 4,616Wh 5,724Wh
6 hours 4,431Wh 6,648Wh 8,311Wh
8 hours 5,724Wh 8,681Wh 10,898Wh

Which systems cover that

The calculator sizes the inverter at one and a half times the running watts, so this AC needs about 2,550W of output. In its list that leaves only the Apex 300 family at 3,840W. The Explorer 2000 v2 at 2,200W and the Comvolt 6000 Pro at 2,500W both fall short.

Matched against rated capacity, one day at a time:

  • Apex 300, 2,764Wh: 2 hours on a mild or warm night.
  • Apex 300 + B300K, 5,529Wh: 6 mild hours, 4 warm hours, or 2 hot hours.
  • Apex 300 + 2x B300K, 8,294Wh: 8 mild hours, 6 warm hours, or 4 hot hours.
  • 8 warm or hot hours, or 6 hot hours: more than the 8,294Wh bundle. The Apex listing allows up to six B300K in total.

These tables leave no reserve. Our product listings plan on 85% of rated capacity for runtime, which would shorten every line, so stay a step below the limit.

A 12V battery bank

Eight warm hours plus the same fridge is about 678Ah a day, which the calculator rounds to an 800Ah bank for one night. It would pull about 144A from a 12V bank while running, and the same load would ask for about 2,350W of solar. That is why the calculator tells you 12V is the wrong architecture at this size and points to a 24V system.

Ways to reduce it

  • Soft starter: the EasyStart Flex 398 lowers inrush by up to 75%. It helps with starting but does not reduce these watt-hours.
  • A 13,500 BTU unit: about 837Wh an hour on a warm night, if it can cool your rig.
  • A 12V rooftop unit: about 412Wh an hour on a warm night at 10,000 BTU, with less cooling.

Put your own hours and temperatures into our RV solar and battery calculator to size the whole system.