Is the Rich Solar 100A converter too much for my RV battery or shore power?
The RS-PC100 is a 120V AC to 12V DC converter-charger: up to 100A continuous (1,460W) out, with three output levels of about 14.6V, 13.6V and 13.2V (no-load figures). Before you fit one, check two limits: what your battery can accept and what your hookup can supply.
Battery side: maximum charge current
A converter pushes up to its rated amps into a low battery, so compare 100A with your battery's listed maximum charge current:
| Battery | Max charge current (listed) | 100A converter? |
|---|---|---|
| Rich Solar 12V 20Ah | 20A | No, five times its limit |
| ALPHA 1, 1 LITE, 1 PRO (100Ah) | 100A | Yes, at its limit |
| ALPHA 2, 2 PRO (200Ah) | 100A | Yes |
| ALPHA 2 LITE (200Ah) | 200A | Yes |
| ALPHA 3 PRO, 3 MINI (314Ah) | 200A | Yes |
| ALPHA 3, 3 LITE (300Ah) | 300A | Yes |
With a small battery, use a charger sized for it. Rich Solar's 12V 20A LiFePO4 charger matches the 20Ah battery. On a single 100Ah ALPHA 1, the converter runs at the battery's ceiling. If the converter also feeds the RV's 12V loads while charging, the battery sees a little less.
Voltage check: Rich Solar lists the ALPHA batteries' charging voltage as 14.4V. The converter's top stage is listed at about 14.6V with no load. Ask us before you rely on this pairing for daily full charges.
AC side: what it draws
The listing gives a maximum AC current of 15A at 120V.
- 30A RV pedestal: about half the service, which leaves roughly 15A for the air conditioner, microwave and everything else. Running the AC and a fully loaded converter at the same time can trip the pedestal breaker.
- 15A household outlet or extension cord: the converter alone can use all of it.
- Generator: 1,460W out at the listed 85% efficiency is about 1,720W in. A 2,000W inverter generator can carry the converter, but not much more alongside it.
When it's the right size
A 300Ah or larger lithium bank with a 30A or 50A hookup, or a generator you want to run for as little time as possible. For a single 100Ah battery on a 30A trailer, it runs at that battery's limit and uses half the pedestal, so a smaller converter leaves more margin on both.
More Rich Solar guides: Is Rich Solar a good brand?
Shop all Rich Solar LiFePO4 batteries.
Shop the full Rich Solar range at RV Parts Giant.
What you need
-
Rich Solar 100 Amp Power Converter 100A 120V Battery Charger
$198.99
-
Rich Solar ALPHA 1 12V 100Ah LiFePO4 Battery
$473.99
-
Rich Solar ALPHA 3 12V 300Ah LiFePO4 Battery
$1,423.99
-
Rich Solar 12V 20Ah LiFePO4 Battery 256Wh Lithium Battery, 3,000+ Cycles
$123.49
-
Rich Solar 12V(14.4V) 20A 100-240VAC
$114.61
Want the full walkthrough? Read the complete guide.