Can I plug a Rich Solar panel into a power station with an 8mm or Anderson input?

Answered by RV Parts Giant · Upland, CA · October 25, 2026

Short answer: Yes, with an adapter, as long as you stay inside its limits. The RS-M2J solar-to-8mm cable is rated 13A and 36V. That covers one 12V MEGA 100 or MEGA 200, or two MEGA 100s in parallel, but not two 12V panels in series or a 24V PRO panel. The RS-A2M handles Anderson inputs. Check the station's own input limits too.

Rich Solar's rigid and briefcase panels end in standard MC4-style solar connectors. Most portable power stations take a different plug, so you need an adapter cable. Two of them are Rich Solar's.

The two adapters

Adapter From / to Ratings
RS-M2J Solar connectors to an 8mm plug 14AWG, 10 ft, 13A, 36V
RS-A2M Solar connectors to an Anderson plug Red wire = solar positive, black = solar negative; no current or voltage rating listed

What fits through the 8mm cable

The RS-M2J's 36V and 13A are the limits that matter. Compare them with the panel's open-circuit voltage (Voc) and short-circuit current (Isc), not its working figures.

Panel setup Voc Isc On the 8mm adapter?
1 x MEGA 100 22.8V 5.78A Yes
1 x MEGA 200 21.8V 11.6A Yes
2 x MEGA 100 in parallel 22.8V 11.6A Yes (with a 2-to-1 Y-branch)
1 x MEGA 250 22.8V 13.7A No, over 13A
2 x MEGA 100 in series 45.6V 5.78A No, over 36V
1 x MEGA 200 PRO (24V) 43.5V 5.93A No, over 36V

So on an 8mm input, stick to one 12V panel, or two small 12V panels in parallel.

Anderson inputs

The RS-A2M listing gives the polarity but no current or voltage rating, so the limits come from your station. Check its solar input voltage window and maximum amps against the table above, adding the panels' figures the same way: series adds volts, parallel adds amps.

Before you plug in

  • Check the station's solar input range on its spec sheet or label. If it's lower than the adapter's, the station sets the limit.
  • Set up the panel in the sun only after the adapter is connected to the station. That way you're not handling live connectors.
  • The adapter itself is 10 ft of 14AWG. To reach a sunny spot further away, add a 10AWG solar extension on the panel side of the adapter.

More Rich Solar guides: Rich Solar vs Renogy and Is Rich Solar a good brand?

Shop all Rich Solar solar kits.

What you need

Want the full walkthrough? Read the complete guide.

Have a different question? Tell us your rig and what you're trying to do. Ask an expert