Rich Solar PV disconnect switch: do I need the 2-pole or the 4-pole version?

Answered by RV Parts Giant · Upland, CA · October 25, 2026

Short answer: Count your PV strings. The 2-pole RS-i2 isolates one string, meaning one positive and one negative pair coming down from the roof. The 4-pole RS-i4 isolates two separate strings with one handle, for example two panel groups running to two controllers. Both are UL 508I listed and rated 1500V and IP66, and both switch in under 3 ms.

A PV disconnect lets you cut the panels off from the charge controller before you work on the wiring. That matters because panels in daylight are always live. Rich Solar makes the same switch in two versions, and the choice depends on how many separate strings come down from the roof.

Count your strings

A string is one positive and one negative pair from the array to a controller input, whether it carries one panel, a series run or a group of panels joined in parallel on the roof.

Your wiring Switch
One pair of PV wires to one controller RS-i2, 2 poles, 1 string
Two pairs: two panel groups, two controllers, or a controller with two PV inputs RS-i4, 4 poles, 2 strings, one handle for both

If you have two strings but only one controller input, you've already combined them somewhere, so it's one string at the switch. Use the RS-i2 after the combiner.

Same switch, two sizes

RS-i2 RS-i4
Poles / strings 2 poles in series, 1 string 4 poles in series, 2 strings
Rated insulation voltage 1500V 1500V
Housing size (H x W x D) 9.8 x 3.8 x 4.3 in 7.1 x 6.8 x 4.3 in
Weight 1.3 lb 1.6 lb

Both versions break the circuit in under 3 ms, are rated IP66 for outdoor mounting, and have a lockable SAFE-LOCK handle so nobody switches the array back on while you work. Both carry UL 508I and CE marks and a 3-year warranty.

Which current figure to use

Rich Solar's product titles say 32A, while the spec tables list a 40A rated thermal current. Plan on the lower 32A. Add up the short-circuit amps of the panels on each string and stay under it. For example, two MEGA 200s in parallel come to 23.2A, but three come to 34.8A, which is over.

The connector rule

Rich Solar's listing warns that you shouldn't mix MC4-style connectors from different brands. Use only the connectors and terminals supplied with the switch, crimp them with the correct tool, and push each one in until it clicks. Rich Solar warns that skipping this can cause overheating, fire or equipment damage.

Mount the switch where you can reach it, between the roof entry and the controller, so you can isolate the array without going onto the roof.

More Rich Solar guides: Is Rich Solar a good brand?

Shop all Rich Solar solar kits.

What you need

Have a different question? Tell us your rig and what you're trying to do. Ask an expert