Can a Sterling Pro Latch-R relay work as a low-voltage disconnect on a lithium RV battery?

Answered by RV Parts Giant · Upland, CA · November 13, 2026

Short answer: Yes. Set the LR80, LR160 or LR240 to battery-protect mode and move the trip points with a magnetic swipe: off anywhere from 10.0 to 14.6V, on from 10.4 to 15V, which covers lithium. It draws about 0.5mA. Budget for the LRR remote too: Sterling says it is needed to switch the relay back on after a protect trip.

Yes. Sterling's Pro Latch-R relays have three modes (split charging, battery protection and engine-start protection), and battery-protect mode is a low-voltage disconnect. Because the contacts latch, the relay only needs a short pulse to switch and Sterling rates the control circuit at about 0.5mA, so it does not eat the small surplus a solar panel makes while you are parked.

Setting it for lithium

The factory trip points are adjustable with a magnetic swipe, and Sterling calls that out as useful for lithium banks.

Setting 12V range 24V range
Off (disconnect) 10.0 to 14.6V 20.0 to 29.2V
On (reconnect) 10.4 to 15V 20.8 to 30V

The relay picks 12V or 24V on its own: it powers up as 12V below 16.5V and as 24V above 17V. Use the cut-off and restart voltages your battery maker publishes and set the relay inside them, so the relay disconnects the loads before the battery's own BMS has to.

What happens at a trip

In battery-protect mode the relay warns before it cuts: power goes off for 10 seconds, then back on for 1 minute so you can start the engine or a charger, then it disconnects. After that, Sterling says the LRR remote is needed to reset the relay. The LRR also gives a 1-minute emergency override (hold select for 5 seconds), shows input or output voltage, alarms at 16V (32V on 24V systems) and can isolate the bank by hand. It ships with 5 m of cable, extendable with standard telephone cable.

So plan on buying the relay and the LRR for this job.

Which size

Relay Continuous Intermittent Output stud
LR80 80A 500A 6 mm
LR160 160A 1000A 8 mm
LR240 240A 1500A 8 mm

Size to the total current of the loads you are protecting. If an inverter sits on that circuit, size to the inverter's DC draw. One relay protects the circuit it is wired into; loads wired straight to the battery are not covered.

Want help picking trip points for your battery? Ask us; we ship from Upland, California.

What you need

Want the full walkthrough? Read the complete guide.

Have a different question? Tell us your rig and what you're trying to do. Ask an expert