Automatic or manual changeover between shore power, generator and inverter: which Sterling switch?

Answered by RV Parts Giant · Upland, CA · November 13, 2026

Short answer: The AC32A Pro Switch is automatic: shore power has priority, then generator, then inverter, with a 0.25 second break and a 10 second generator delay. The SC16A, SC20A, SC32A and SC63A are manual 3-source selector switches. Both keep only one source on your AC panel at a time; size by your inlet amps.

If your RV, van or boat has three AC sources feeding one panel, something has to make sure only one is connected at a time, so the generator never back-feeds the shore pedestal or the inverter. Sterling makes an automatic switch and a manual one.

Automatic: AC32A Pro Switch

  • 3 prioritized channels. Channel 1 (shore) beats channel 2 (generator), which beats channel 3 (inverter). Plug in at a campground and shore power takes over from the inverter on its own.
  • 0.25 second break-before-make delay to protect sensitive equipment.
  • 10 second delay on the generator input so it can settle after starting.
  • Powered from the AC sources, not the batteries, so it still switches with flat batteries.
  • Breaks both live and neutral, with 6 internal fuses fusing both.
  • Lock-out relay to drop heavy loads, such as a water heater or battery charger, while the inverter is the source.
  • Reverse polarity indication on the shore input, and a remote panel (ACRC) on a 10 m cable showing the active source, available sources and faults.
  • Rated 32A (40A internal switch), 110-230V AC.

Manual: SC-series selector switches

The SC16A, SC20A, SC32A and SC63A are rotary selectors for 3 sources and 1 output, rated 16, 20, 32 and 63A, up to 300V AC, with a waterproof front panel. You choose the source by hand. There is no priority logic, no delays and no load lock-out.

Decision rule

You want Pick
Shore power to take over without thinking about it, and loads like the water heater kept off the inverter AC32A
A simple, compact switch and you are happy to turn a knob SC-series
A source bigger than 32A SC63A (manual is the only Sterling option above 32A here)

Sizing: match the rating to the largest source, normally the shore inlet. On a 30-amp RV inlet, the 32A models cover it. A 50-amp RV inlet has two 50A legs; none of these listings describe a two-leg setup, so ask us before ordering for a 50-amp rig.

Fitting a changeover switch means working inside the AC panel, so have a qualified electrician do the install. Ask us if you want help choosing; we ship from Upland, California.

What you need

Have a different question? Tell us your rig and what you're trying to do. Ask an expert