How long does it take to recharge a BigBattery Husky 2 or Eagle 2 on shore power?

Answered by RV Parts Giant · Upland, CA · November 22, 2026

Short answer: About 5.7 hours for the 12V 400Ah Husky 2 on its 60A charger or the 24V 200Ah on its 30A charger, refilling 85% of capacity. The 48V 100Ah takes about 4.3 hours at 20A. Eagle 2 batteries take roughly 1.4 to 1.8 hours. Allow extra time at the end of the charge.

The math is amp-hours to replace, divided by charger amps. We use the 85% usable figure from our RV solar and battery calculator, so each time below is a refill from that working low point.

Battery Ah to replace Listed charger Minimum time
Husky 2 12V, 400Ah 340 PWS015, 60A about 5.7 hours
Husky 2 24V, 200Ah 170 PWS051, 30A about 5.7 hours
Husky 2 48V, 100Ah 85 PWS053, 20A about 4.3 hours
Eagle 2 24V, 64Ah 54 PWS051, 30A about 1.8 hours
Eagle 2 48V, 32Ah 27 PWS053, 20A about 1.4 hours

These are minimum times at full rated current. The battery listings don't state a maximum charge current, so use the charger BigBattery pairs with each one. Chargers taper near the top and any load running in the RV takes some of the current, so a real refill runs longer.

What this means at a campground or on a generator

A 12V Husky 2 is an overnight charge, not a lunch stop. Two hours on the 60A charger puts back about 120Ah, a little over a third of the usable capacity. If you run a generator in two-hour windows, plan on three of them for a full refill.

The 60A charger puts out 14.6V, so it delivers up to about 876W. It draws more than that from the outlet. Leave room for it beside a microwave, water heater or other large load on the same supply.

Three checks before ordering

  1. Match the voltage exactly. PWS015 outputs 14.6V, PWS051 outputs 28.8V and PWS053 outputs 57.6V. They don't interchange.
  2. Check the AC input. PWS015 and PWS053 are listed at 110V. The PWS051 listing doesn't state its input, so ask us before using it on an RV supply. The larger PWS012 48V 50A charger is 220V and is only listed for the Inverter Version of the Husky 2.
  3. Match the battery family. BigBattery lists PWS015 for the 12V Husky 2, and lists PWS051 and PWS053 for both Husky 2 and Eagle 2 at their voltages.

If the hours are far off

Read the current on a battery meter while charging. Well below the rated amps early in the charge points to a load on the bank, a poor connection, or a battery that is already nearly full. If the charger shows nothing at all, check the AC supply and the DC ring-terminal connections first, then contact us with both part numbers.

What you need

Have a different question? Tell us your rig and what you're trying to do. Ask an expert