Do I need the Spartan Power 300A or 600A battery switch for my RV inverter?

Answered by RV Parts Giant · Upland, CA · November 18, 2026

Short answer: Size it to the inverter's DC current. On 12V a 2000W inverter pulls about 181A and a 3000W about 272A, both inside the 300A switch. A 3300W inverter charger is about 299A and a 4400W about 399A, so use the 600A. On a 48V bank pick the 300A on/off: the 600A is rated to 32V.

A battery switch has to carry the inverter's full DC current continuously, so start from the inverter, not the battery.

Work out the DC current

DC amps ≈ inverter watts ÷ 0.92 efficiency ÷ 12V (the assumptions our RV solar & battery calculator uses):

Inverter at full load 12V DC current Switch
2000W about 181A 300A
3000W about 272A 300A, little headroom
3300W (Spartan SP-IC3312) about 299A 600A
4400W about 399A 600A

At 24V the current halves, and at 48V it is a quarter, so a 300A switch covers most 24V and 48V inverters.

The three Spartan switches

SP-BS300A on/off SP-BS300A-4P selector SP-BS600A on/off
Continuous 300A 300A 600A
5 minutes 500A 500A 900A
Cranking (30 s) 900A 900A 1750A
Max voltage 48V DC 32V DC 32V DC
Studs and torque 3/8 in (M10), 120 in-lb 3/8 in (M10), 120 in-lb 1/2 in (M12), 220 in-lb
Cable to meet rating 4/0 AWG 4/0 AWG two 4/0 AWG

How to choose

  • One bank, inverter to about 3000W on 12V: the 300A on/off. It is also the only one of the three rated for a 48V bank.
  • Two banks you want to isolate or join: the 300A 4-position selector. It switches either bank to the loads or combines both, with make-before-break contacts so power is not interrupted as you switch. It is a 12V or 24V part (32V max).
  • 12V inverter charger of 3300W or more: the 600A on/off. Order lugs for 1/2 in studs, not 3/8 in.

Checks

  1. Lug size. The 300A switches take 3/8 in lugs; the 600A takes 1/2 in. Lugs cut for one will not fit the other.
  2. Cable. Spartan rates the switches with 4/0 AWG. Thinner cable is the weak link, not the switch.
  3. Fuse. A switch is not overcurrent protection. Keep a fuse in the positive cable near the battery, sized for the cable.

What you need

Have a different question? Tell us your rig and what you're trying to do. Ask an expert