Do I need the Spartan Power 300A or 600A battery switch for my RV inverter?
Short answer: Size it to the inverter's DC current. On 12V a 2000W inverter pulls about 181A and a 3000W about 272A, both inside the 300A switch. A 3300W inverter charger is about 299A and a 4400W about 399A, so use the 600A. On a 48V bank pick the 300A on/off: the 600A is rated to 32V.
A battery switch has to carry the inverter's full DC current continuously, so start from the inverter, not the battery.
Work out the DC current
DC amps ≈ inverter watts ÷ 0.92 efficiency ÷ 12V (the assumptions our RV solar & battery calculator uses):
| Inverter at full load | 12V DC current | Switch |
|---|---|---|
| 2000W | about 181A | 300A |
| 3000W | about 272A | 300A, little headroom |
| 3300W (Spartan SP-IC3312) | about 299A | 600A |
| 4400W | about 399A | 600A |
At 24V the current halves, and at 48V it is a quarter, so a 300A switch covers most 24V and 48V inverters.
The three Spartan switches
| SP-BS300A on/off | SP-BS300A-4P selector | SP-BS600A on/off | |
|---|---|---|---|
| Continuous | 300A | 300A | 600A |
| 5 minutes | 500A | 500A | 900A |
| Cranking (30 s) | 900A | 900A | 1750A |
| Max voltage | 48V DC | 32V DC | 32V DC |
| Studs and torque | 3/8 in (M10), 120 in-lb | 3/8 in (M10), 120 in-lb | 1/2 in (M12), 220 in-lb |
| Cable to meet rating | 4/0 AWG | 4/0 AWG | two 4/0 AWG |
How to choose
- One bank, inverter to about 3000W on 12V: the 300A on/off. It is also the only one of the three rated for a 48V bank.
- Two banks you want to isolate or join: the 300A 4-position selector. It switches either bank to the loads or combines both, with make-before-break contacts so power is not interrupted as you switch. It is a 12V or 24V part (32V max).
- 12V inverter charger of 3300W or more: the 600A on/off. Order lugs for 1/2 in studs, not 3/8 in.
Checks
- Lug size. The 300A switches take 3/8 in lugs; the 600A takes 1/2 in. Lugs cut for one will not fit the other.
- Cable. Spartan rates the switches with 4/0 AWG. Thinner cable is the weak link, not the switch.
- Fuse. A switch is not overcurrent protection. Keep a fuse in the positive cable near the battery, sized for the cable.