The 12V fan is the most important part of a Nature's Head. It dries the solids and vents odor outside. If it stops, the toilet starts to smell within a day or two. Here's how to find the fault.
1. Check power at the source
- Is the 12V supply on? Check the switch, the RV breaker or fuse panel, and the battery.
- On a cigarette-lighter setup, try another socket. The 12V cigarette lighter power kit is the simplest plug-in option.
- For testing at home, use the 110V AC adapter.
2. Check the inline fuse
A blown fuse is the most common fault. Replace it with a spare fuse, and the fuse housing if it's cracked or corroded.
3. Check the cable
Look for a loose barrel plug or a pinched wire. The 6 ft 12V fan cable is cheap to replace.
4. Check the fan
- With power confirmed, listen and feel at the outside vent.
- A clogged fan filter can choke airflow. Replace it.
- If it still won't spin, replace the fan assembly.
Which replacement fan?
- High-CFM fan assembly ($47.99): a 40 x 15 mm fan with an IP67 coating, so it's dust and water proof. It moves more air without extra noise, and its WAGO connectors make future fan swaps easier. It's standard on new Nature's Head toilets from August 2026 and is the recommended upgrade.
- Original fan assembly ($15): a like-for-like replacement for the original 10 mm fan.
Still not right?
If the fan runs but the toilet still smells, see composting toilet smell: causes and fixes and our power and vent guide.