Lippert Schwintek in-wall slide blinking red? Hydraulic slide pump runs but the room won't move? Lippert's error codes, reset, overrides and the parts that fix them.

First, work out which slide system you have, because the fixes are different. Lippert's two common systems are the in-wall (Schwintek) slide, with two small motors hidden in the side walls of the room, and the hydraulic slide, with a pump, a reservoir and cylinders under the floor. If you see a pump and a fluid reservoir in a compartment, it's hydraulic. If there's a small controller box with red and green LEDs and no pump, it's almost certainly an in-wall system.

Safety first: keep everyone clear of the room while it moves, and support the room as your RV's manual directs before opening any hydraulic line. The system holds pressure.

Schwintek in-wall slides

Check the battery before anything else

Lippert says the controller can run on as little as 8 V, but if you measure less than 11 V at the controller, charge the battery first. Never jump-start or charge through the controller's terminals. Lippert specifies a 30 A fuse at minimum. Low voltage is a common reason an in-wall room moves crooked or stops.

Read the error code

The controller blinks green to show which motor is involved (once for motor 1, twice for motor 2), and blinks red to show the fault:

Red blinks Meaning (Lippert) What to check
2 Battery dropout: below 6 V while running Battery charge, connections, fuse
3 Low battery: below 8 V at the start Charge the battery
4 High battery: above 18 V Charger or converter output
5 Excessive motor current Obstruction, binding, debris in the gear rack
6 Motor short circuit Motor wiring; the motor itself
8 Hall signal not present Motor connector and harness; the motor's sensor
9 Hall power shorted to ground Damaged motor harness

Reset

Lippert says one press of the extend/retract switch resets the board. Press it again to run the room normally.

Getting the room in when it won't retract

Lippert documents three overrides for in-wall slides:

  1. Electronic override (board revision C1 and newer): press the controller's mode button six times quickly, and hold it on the seventh press for about 5 seconds. The red and green LEDs flash, and you can then run the room from the wall switch. It times out after 60 seconds.
  2. Unplug the motors: unplugging both motors releases their brakes so the room can be pushed in. Plug them back in to re-apply the brakes before you travel.
  3. Disengage a motor: remove the motor retention screw, lift the motor about 1/2 inch to disengage it, push the room in, and travel-lock the room.

If the room is stuck in, Lippert marks the procedure "dealer only" because it involves removing the exterior fascia.

Replacing an in-wall motor

Lippert's motor is 236575, an IG-42 10 mm motor, supplied with its harness. Lippert's page lists RV-maker cross-references including Jayco 0211019, Keystone 349955 and Grand Design 170000. Check the gear ratio on your old motor before ordering a replacement. In-wall motors come in different ratios, and they aren't interchangeable.

Lippert hydraulic slides

The pump doesn't run

Check the battery, the fuse and the pump solenoid before you replace the power unit. A pump that stays silent often has a power problem, not a pump problem.

The pump runs but the room won't move

  • Fluid level. Lippert specifies Type A automatic transmission fluid, with Dexron III or Mercon V recommended. The reservoir holds about 2 quarts. Lippert says the system purges itself of air after 2–3 full cycles.
  • Leaks. A cylinder that is wet with fluid, or a weeping hose fitting, is the part to replace.

Manual override (through-frame hydraulic)

Lippert's owner's manual describes a drill override on the pump. Remove the protective label, put a hex bit in a drill, and turn the motor shaft: counterclockwise extends and clockwise retracts. Lippert says a 38-inch room takes about 45 seconds this way.

Hydraulic parts

Not sure which pump or cylinder you have? Which Lippert hydraulic slide-out pump or cylinder replaces mine? lists the specs to check.

FAQ

Why does my in-wall slide go out crooked?

Usually one of the two motors is slowing or stalling. Low battery voltage is the first thing Lippert has you check. If the controller shows a red code, start with the table above.

Can I use any ATF in my hydraulic slide?

Lippert specifies Type A ATF and recommends Dexron III or Mercon V. Check your RV's manual in case your system calls for something else.

More slide-out and Lippert parts are in our Lippert collection and the BAL slide-out and jack collection.