The pump this guide covers: the SEAFLO 42 Series 12V RV water pump (3.0 GPM, 55 PSI). The same steps apply to the 43 Series, the quick-connect version of the same pump.
The SEAFLO 42 Series has two adjustment screws: the pressure switch, which sets the pressure at which the pump shuts off, and the bypass valve, which keeps the flow smooth when only a little water is being drawn. Both come set from the factory, and SEAFLO recommends leaving adjustment to a technician with a pressure gauge. If you do adjust them, this is SEAFLO's procedure.
Should you adjust it at all?
Usually not. SEAFLO's spec sheet lists the 42 Series shut-off as adjustable from 45 to 65 PSI, factory set to 55 PSI. Most RV problems that look like a "bad pressure switch" are really something else:
- Pump cycles on and off with the taps closed: usually a leak on the outlet side. Find the leak first.
- Pulsing at low flow: kinks, undersized lines, dirty aerators or filters, or air leaks. See why an RV pump pulses with a tap open.
- Won't shut off: low voltage at the pump is a common cause. Check the voltage before touching the switch.
Turning the switch up to hide a leak or a voltage problem just leaves you with a pump that doesn't shut off.
How the switch and bypass work together
When a faucet is open, the pump runs at full flow and the bypass valve stays closed. As demand drops, the spring-loaded bypass opens and lets water circulate from the outlet back to the inlet inside the pump head. That keeps the flow steady with almost no cycling. When every faucet is closed, pressure rises to the switch's shut-off point and the pump stops.
SEAFLO's key rule: full bypass pressure must be at least 8 PSI higher than the shut-off pressure. If the two are set too close together, they overlap and the pump won't shut off.
Setup: you need a gauge
- Plumb the pump from the tank to a pressure gauge, then a shut-off valve, then an open outlet (SEAFLO's test setup).
- Have a 2 mm Allen (hex) key ready.
- Run the pump with the valve open until there's no air, then close the valve slowly and watch where the gauge settles when the pump stops.
Adjusting the shut-off pressure
- Unscrew the front cover of the pressure switch.
- To raise the shut-off pressure, turn the switch screw clockwise with the 2 mm Allen key.
- To lower it, turn the screw counter-clockwise.
- Make small changes, then open and close the valve and read the gauge again. Stay within the 45–65 PSI range.
- Refit the cover.
Adjusting the bypass
- Clockwise raises the pressure at which the bypass starts and its full-bypass pressure.
- Counter-clockwise lowers both.
- After any change, confirm full bypass is still at least 8 PSI above the shut-off pressure.
SEAFLO's manual warns that adjusting the bypass the wrong way can damage the pump, and that damage from use outside the manual isn't covered by warranty.
How high is too high?
More pressure isn't always better. Our RV water pump buying guide puts the sweet spot for most campers at 45–55 PSI. Higher settings stress fittings and faucets, and most RV water heaters have an 80 PSI maximum inlet. Check the ratings of everything downstream before you go above the 55 PSI factory setting.
Is the switch bad?
SEAFLO's troubleshooting lists a failed or defective pressure switch as a cause of both "motor won't turn on" and "won't turn off". Rule out the other causes first:
| Symptom | Rule these out first | Then suspect |
|---|---|---|
| Motor won't start | Loose wiring, no power, blown fuse, tripped thermal protection | Pressure switch, motor |
| Won't shut off | Outlet-side leak, low voltage, clogged valves, punctured diaphragm | Pressure switch, bypass set too close to shut-off |
The pressure switch is a separate part in SEAFLO's 42 Series repair kit list, along with the pump head, valve, diaphragm and motor assemblies, so a bad switch doesn't always mean a new pump. If the pump is old or has several faults, a new 42 Series pump is often the quicker fix.
FAQ
What's the factory setting? 55 PSI shut-off, adjustable 45–65 PSI, per SEAFLO's spec sheet.
What tool do I need? A 2 mm Allen key, plus a pressure gauge to set it accurately.
Which way raises the pressure? Clockwise, for both the switch and the bypass.
I turned it up and now it won't shut off. The bypass and the switch are probably overlapping. Lower the shut-off, or raise the bypass, until full bypass is at least 8 PSI above shut-off.
Will an accumulator help? SEAFLO designed the 42 Series' bypass to reduce cycling without one, but an accumulator tank on the pressure side still smooths pulsing at very low flow. See RV water pump cycling on and off.