Do I need a solar rapid shutdown switch or just a DC disconnect on my RV?
They solve different problems. The question is where you want the solar power to stop, and whether it should stop on its own.
The three AIMS parts compared
| Rapid shutdown, PVRSD1 | DC disconnect, DC1200V32A | Cable entry port, PV-2WEGMC4 | |
|---|---|---|---|
| What it is | Rapid Solar Disconnect plus a Cable Entry Port, prewired | Manual quick-disconnect switch | Roof pass-through for two PV wires |
| Where power stops | At the PV module level, on the roof | Between the panels and the controller, battery or inverter | Doesn't switch anything |
| How you turn it off | From an accessible spot inside, no roof climb | By hand at the switch | n/a |
| Automatic shutdown | Yes, if no 12V is present (battery failed or disconnected) | No | No |
| Rating listed | not listed | 1,200V DC, 32A | n/a |
| Connectors | MC4-compatible CEP | MC4-compatible in and out | MC4 leads, 10 in or 10 ft |
Which one you need
- New build, dealer install or a full rewire: the PVRSD1. AIMS states this type of solution is required by RVIA for safety compliance, and it is the only one of the three that de-energizes the roof wiring itself. It already includes the cable entry port, so you don't buy one separately.
- You just want to isolate the array for service: the DC1200V32A switch lets you cut panel power to the charge controller before you work on the controller or battery. The wiring from the roof down to the switch stays live in daylight.
- Only routing wires through the roof: the PV-2WEGMC4 entry port. Pick the 10 in leads if the controller sits right under the entry point, the PV-2WEGMC4-10FT if you need to run 10 ft before the first connection.
The detail people miss
A manual disconnect only works if someone switches it. The rapid shutdown's automatic trip covers the case where the battery fails or is disconnected: AIMS designed it so voltage and current stop at the panels instead of travelling into the RV.
Check the 32A rating against your array's current before you use the DC1200V32A on a large array; panel current is on each panel's label. Not sure? Ask us. RV Parts Giant ships from Upland, California.