Do I need a SmartShunt with a Victron SmallBMS NG or VE.Bus BMS NG?
On older Victron lithium builds a SmartShunt was standard kit, because the shunt was the only thing that counted amp-hours. Lithium NG changed that: the batteries report their own numbers to the BMS.
Why the shunt is redundant here
Victron's listings for both NG units say it directly:
- SmallBMS NG: receives current and state of charge data from the batteries, "so there's no need for a separate SmartShunt."
- VE.Bus BMS NG: takes voltage, current, state of charge and individual cell data from the battery, removing the need for a separate SmartShunt.
Both have Bluetooth, so VictronConnect shows the whole bank from the BMS. Put the shunt money toward the right BMS instead.
Which NG BMS, then
| Your system | Order |
|---|---|
| MultiPlus, Quattro or another VE.Bus inverter/charger | VE.Bus BMS NG (BMS300200300) |
| No VE.Bus inverter/charger: DC loads, a standalone inverter, chargers with remote on/off | SmallBMS NG (BMS400100300) |
| Lynx DC distribution with a built-in contactor | Lynx Smart BMS NG (see our Lynx BMS answer) |
The SmallBMS NG is not suitable for MultiPlus or Quattro, because it has no VE.Bus communication.
What each output should be wired to
Both units have the same three outputs. They do nothing until something is wired to them:
- Load disconnect: the remote on/off of a Smart BatteryProtect, an inverter, a DC-DC converter or any load with remote on/off. This is what stops deep discharge.
- Charge disconnect: the remote port of a Smart IP43 charger, a Cyrix-Li-Charge relay, a Cyrix-Li-ct combiner or a BatteryProtect. This is what stops over-charging.
- Pre-alarm: a relay, LED or buzzer that warns before the load disconnect acts.
A charger or load that has no remote on/off input cannot be switched off by the BMS. Check every charge source (solar, DC-DC, converter) has one, or put it behind a BatteryProtect or Cyrix that does.
Limits worth knowing
- Battery type: NG only. Neither unit works with the older Lithium Battery Smart range.
- Bank size: up to 50 batteries in a 12V or 24V bank and 25 in a 48V bank, in series, parallel or both.
Send us your inverter model and every charge source and we will confirm the BMS and what each output connects to.
What you need
Want the full walkthrough? Read the complete guide.