What size generator do I need to run a Sterling Pro Charge Ultra battery charger?

Answered by RV Parts Giant · Upland, CA · November 13, 2026

Short answer: Sterling suggests about twice the charger's AC draw for cold starts: 700W for the 12V 20A, 1,000W for 30A, 1,200W for 40A, 1,500W for 50A and 1,800W for the 60A. If your generator is smaller, dial the charger back to 75, 50 or 25 percent from its front panel; the active power factor correction lets it run cleanly on generator power.

Sterling lists the AC draw of each Pro Charge Ultra charger and a suggested generator size for cold starts, which is about double the running draw. The table is straight from those listings.

Draw and suggested generator

Charger DC output AC draw (about) Sterling's suggested generator Draw on 120V shore power*
PCU1220 12V, 20A 350W 700W about 3A
PCU1230 12V, 30A 500W 1,000W about 4A
PCU1240 12V, 40A 600W 1,200W about 5A
PCU1250 12V, 50A 750W 1,500W about 6A
PCU1260 12V, 60A 900W 1,800W about 7.5A
PCU2420 24V, 20A 600W 1,200W about 5A
PCU2430 24V, 30A 900W 1,800W about 7.5A
PCU4815 48V, 15A 900W 1,800W about 7.5A

*Our arithmetic: AC draw divided by 120V, rounded.

If your generator is smaller

Every model has an output reduction setting of 75%, 50% or 25%, set from the front panel, meant for weak shore power and small generators. Turning a PCU1260 down to 50%, for example, roughly halves its 900W draw (our arithmetic), which brings it inside the range Sterling gives for the PCU1230. You charge slower, but the generator does not overload.

Remember the generator is usually running other things too. If the microwave or air conditioner is on at the same time, add their watts before you pick a charger setting.

Why it copes with generators

The Pro Charge Ultra has active power factor correction and accepts 80-270V AC at 40-70Hz, so Sterling says it runs cleanly on generators, including ones with a rougher waveform. It also has three isolated outputs (engine, house and a third bank), 11 charge profiles including LiFePO4 plus a custom one, and a battery temperature sensor in the box. The optional PCUR remote puts the controls where you can reach them.

Picking the size in the first place

Charger amps are a battery decision first: check your battery maker's maximum charge current, then make sure the generator you carry can feed that charger. Not sure? Send us the battery and generator details; we ship from Upland, California.

What you need

Want the full walkthrough? Read the complete guide.

Have a different question? Tell us your rig and what you're trying to do. Ask an expert