A dead Kwikee step is usually not a dead motor. Lippert's manuals put power, ground, fuses and switches ahead of the motor in the troubleshooting order, and those are cheaper to fix. Find your symptom below, work through the checks, and only then order parts. When you do need a motor, our guide Which Kwikee Step Motor Do I Need? matches it to your step's series and year.
Safety first: disconnect 12 V power before you unplug anything under the step, and support the coach as its maker specifies before you work underneath.
Know how the control thinks
On IMGL-era steps, the control unit watches motor current. If the step hits a curb or an obstruction, or the frame is bent and binding, the current rises and the control cuts power to the motor. So a step that stops partway may be a control doing its job. Lippert also designs the step to retract by itself when the ignition is turned on with the door closed.
Symptom: nothing happens at all
- Battery. A good, charged battery reads about 12.6 V with no load. Lippert says low voltage or a poor ground causes erratic operation, and no voltage means no step.
- Battery disconnect. If the coach's disconnect switch is off, the step won't run.
- Fuses. Lippert's wiring calls for a 20–25 A fuse or breaker on the main power. The override circuit has a 6 A inline fuse.
- Ground. The step won't work if its green ground wire to the chassis is loose or corroded.
- Power at the step. On the harness, red to ground should read at least 12 V.
Symptom: it won't extend when the door opens
- Door switch. Lippert's check is 12 V at the door switch circuit with the door closed and 0 V with it open. No change means a bad switch or wiring, not a bad motor.
- Power or override switch. Make sure the step's switch inside the coach is in the right position.
Symptom: it won't retract
- Override switch left on. With the override (lock-out) switch on, the step is meant to stay out. Turn it off.
- Yellow ignition wire. If the step won't retract when you turn the ignition on with the door closed, check the yellow wire. It must connect to a source that is hot with the ignition on. Lippert notes that if it isn't connected, the step stays out while the override is on.
- Obstruction or bent frame. A step that binds draws high current, and the control shuts it off. Look for curb damage and bent linkage.
Symptom: it stops halfway or runs erratically
- Check battery voltage and the ground first. These are Lippert's first suspects for erratic operation.
- If the step runs straight off the converter, Lippert says the converter must deliver at least 30 A.
- Lubricate the pivot points, slides, clevis pin and linkage every 30 days with a moisture- and heat-resistant penetrating grease. Lippert says not to use silicone sprays or WD-40.
Symptom: the step feels loose or mushy
That is a mechanical adjustment, not an electrical fault. It usually means the cam stops need adjusting. The RV step maintenance guide covers the routine.
Is it the control or the motor?
Lippert's bench test settles it. Unplug the 4-way connector under the step, plug in a 4-way pigtail (Lippert 369243) and run the step from a charged 12 V battery. If any function fails on the bench, the fault is in the control unit and/or the motor. If everything works on the bench, go back to the door switch, power switch and coach wiring. Our Kwikee motor guide walks through the direct motor test and the control shut-off check.
Which replacement part?
| Your step | Part |
|---|---|
| IMGL II (2019+) singles and doubles | 14NM motor 676061 |
| Series 23 triple | 18NM motor 379147 |
| Series 24/25 triples, 42/47 doubles | 25 Series motor 369506 |
| Pre-IMGL (late 1999–2005) | Pre-IMGL motor 379608, or Lippert's preferred IMGL II conversion kit: A linkage 781005, B 781006, C 781007 |
The step's label, under the step on the mounting surface, tells you the series and generation. All of these are genuine Lippert parts with a 1-year Lippert warranty, and they ship free to the lower 48.
FAQ
Why did my step stop working after I replaced the battery?
Check the ground and the main fuse or breaker first. A loose ground or a tripped breaker is the usual cause after battery work.
Can I splice lights into the step wiring?
No. Lippert says the step circuit must stay independent.
My step won't go in and I need to drive. What now?
We couldn't find a manual-retract procedure for a dead motor in Lippert's manuals. Check the override switch and the yellow ignition wire first, since those are the common causes. If the step still won't move, call us or a Lippert-authorized service center before you force it, so you don't damage the linkage.
More Kwikee and Lippert parts are in our Lippert collection.