A Victron SmartShunt or BMV Smart battery monitor counts every amp in and out of the battery to work out state of charge. Out of the box it is set up for a lead-acid battery. On a lithium (LiFePO4) bank, the defaults make the percentage drift and the monitor may not reset to 100% when the battery is full.
These are the settings to change, with Victron's defaults and the values its manuals give for lithium. All of them are in the VictronConnect app under Settings > Battery (or in the BMV's setup menu).
The settings at a glance
| Setting | Default | Lithium (12V bank) |
|---|---|---|
| Battery capacity | 200Ah | Your bank's total Ah |
| Charged voltage | 14.0V | 13.9V (Victron's lithium recommendation) |
| Tail current | 4% | 4% to start; adjust if it syncs too early or never |
| Charged detection time | 3 minutes | 3 minutes |
| Peukert exponent | 1.25 | 1.05 for Victron Smart LiFePO4; 1.01 if unknown |
| Charge efficiency factor | 95% | 99% |
| Discharge floor | 50% | Lower, for example 10-20% |
| Temperature coefficient | 0%cap/°C | 0.5%cap/°C if a temperature sensor is fitted |
For 24V and 48V banks, Victron's recommended lithium charged voltage is 27.8V and 55.6V.
What each setting does
Battery capacity
The total amp-hours of the bank. Two 200Ah 12V batteries in parallel are 400Ah. Two in series for 24V stay 200Ah. Get this wrong and every percentage is wrong.
Charged voltage, tail current and charged detection time
These three decide when the monitor resets itself to 100%. Victron's manual describes it: the battery voltage must be above the charged voltage, the charge current must be below the tail current (a percentage of capacity), and both must hold for the charged detection time. With the defaults on a 200Ah bank, that's above 14.0V and under 8A for 3 minutes.
Set the charged voltage a little below your chargers' absorption voltage. Victron's own lithium batteries use 14.2V absorption and 13.5V float, so 13.9V sits between them and syncs during absorption. If your battery maker uses different charge voltages, keep the charged voltage just under their absorption figure.
Victron warns about both directions. Too low and the monitor can sync falsely, for example on solar as the sun drops. Too high and it never syncs, so the percentage drifts further each day. If you see the percentage jump to 100% before the battery is actually full, lower the tail current. If it never reaches 100% even after a full charge, check the charged voltage first.
Peukert exponent
Peukert corrects for a battery delivering less capacity at high discharge rates. Lead-acid needs a large correction; lithium barely any. Victron's Lithium Battery Smart manual says to set 1.05 for its own lithium batteries. The SmartShunt and BMV manual says to use 1.01 for lithium when you don't know the value. Use your battery maker's figure if they give one.
Charge efficiency factor
How much of the charge current actually ends up stored. The 95% default suits lead-acid. Victron's lithium manual says to set 99%.
Discharge floor
The state of charge you treat as empty. The monitor uses it to calculate time-to-go. Victron says 50% for lead-acid and lower for lithium. LiFePO4 can be used much deeper, so 10-20% is a common choice. That still leaves a margin before the battery's BMS cuts off.
Temperature coefficient
Only relevant if the monitor has a temperature sensor on its aux input. Victron gives 0.5%cap/°C as the typical value for LFP batteries below 20°C.
After you change the settings
- Fully charge the battery so the monitor syncs to 100%, or press Synchronise in VictronConnect once you know the battery is full. Until it syncs, the BMV shows "---" instead of a percentage.
- Set a low state-of-charge alarm if you want a warning before the battery runs low. On the SmartShunt it shows in the app (it has no buzzer or relay). The BMV also has a relay you can use for a low-SoC signal.
- Leave "Battery SOC on reset" on Keep SOC so a firmware update or power loss doesn't reset the reading.
If the readings still look wrong, see why a SmartShunt reads 100% with zero current and why it won't let you set the state of charge.