Is a Victron 275A battery switch big enough for my 12V inverter?
Look at the continuous current rating, because that's what an inverter running a microwave or an air conditioner pulls for minutes at a time. The Victron Battery Switch (VBS127010010) is rated:
| Rating | Value |
|---|---|
| Continuous | 275 A |
| One minute | 455 A |
| Cranking | 1,250 A |
| Max voltage | 60 V (sold for systems up to 48 V) |
| Studs | M10 (3/8 in), tin-plated copper |
| Torque | 70 lbf-in (8 Nm) |
Work out your current
DC amps ≈ inverter watts ÷ 0.92 (efficiency) ÷ 12 V. That's the same assumption our solar and battery calculator uses:
| Inverter at full continuous output | Approx. DC current | Fits 275 A? |
|---|---|---|
| 1,200 W (Phoenix 12/1200) | about 110 A | yes, plenty of headroom |
| 1,500 W (Phoenix 12/1600) | about 136 A | yes |
| 2,000 W | about 181 A | yes |
| 12 V 3,000 VA MultiPlus at full output | about 250 A | yes, but only about 25 A to spare |
| 12 V 4,000 VA or two 3,000 VA units | well over 275 A | no |
At a lower battery voltage, the same watts mean more amps. That's why a 3,000 VA unit is the practical ceiling on 12 V. Add any DC loads that run through the same switch at the same time, such as a 12 V fridge or roof AC, before you compare. The one-minute 455 A rating covers motor start-up surges. It isn't something to run at.
Where it goes and what it isn't
You can surface-mount it or mount it from behind a panel. It has four knock-out side panels for cable entry, and you can remove the knob so nobody can switch it on during work. The listing says it can also parallel the house and starter batteries in an emergency. The switch doesn't protect anything, so you still need a fuse sized to the cable. See the guide for the cable and fuse table.
If you're over 275 A, move up to 24 V. Half the current for the same watts puts a 3,000 VA system around 125 A.
Shop Victron Phoenix inverters, or the full Victron Energy range at RV Parts Giant.
What you need
Want the full walkthrough? Read the complete guide.