What size Victron isolation transformer do I need for a 30-amp RV?
Size the transformer to the shore service, not to what you usually run. Whatever the cord can deliver, the transformer has to carry.
Match the model to your service
| Shore service | Most it can deliver | Victron model |
|---|---|---|
| 15 or 20 amp, 120V | 1,800–2,400W | 2000W 115/230V (ITR040202041) covers 15 amp; at 20 amp it becomes the limit |
| 30 amp, 120V (TT-30) | 3,600W | 3600W 115/230V (ITR040362041) |
| 30 amp, 120V, and you also plug into 230V abroad | 3,600W | 3600W Auto 115/230V (ITR050362041), which selects the input voltage itself |
| 50 amp, 120/240V split-phase | up to 12,000W | none of the four; see below |
| 230V single-phase only | — | 7000W 230V (ITR000702001) |
The arithmetic is amps x volts: 30 x 120 = 3,600W, and a 50-amp RV gets two 50-amp, 120V legs, 2 x 50 x 120 = 12,000W. The 2000W model at 120V works out to about 16.7A, which is why it suits a 15-amp cord but not a 30-amp one.
What it does that a surge protector does not
The transformer separates the RV's AC system from the campground or dock supply, so there is no direct connection through the ground wire. Victron lists two benefits: it helps prevent galvanic corrosion and adds protection against ground faults from shore power.
50-amp rigs: the VDI galvanic isolator
For a 50-amp split-phase RV, Victron's VDI galvanic isolator is listed specifically for split-phase installations. It sits inline in the shore-power ground and blocks the low-voltage galvanic currents that cause corrosion, while still letting a real fault current through to trip the breaker. It is smaller and simpler than a transformer, but it only deals with the ground path; it does not separate the whole AC system. It comes in VDI-16, VDI-32 and VDI-64 versions, matched to the shore connection.
Where it goes
Mount it between the shore inlet and everything else, so the inverter/charger, converter and main panel all sit on the isolated side. Have a qualified electrician make the AC connections, and send us your shore service and inverter/charger model if you want the size confirmed first.