AIMS PICOGLF DIP Switch and Charger Settings Explained

What the five DIP switches and the battery type selector on an AIMS PICOGLF low-frequency inverter charger do, and the settings most RV and lithium owners use.

AIMS PICOGLF inverter charger DC end with DIP switches, battery terminals and remote ports

Every AIMS PICOGLF inverter charger has a small bank of DIP switches and a rotary battery type selector on the DC end of the case. They decide when the inverter cuts out on a low battery, whether it runs from shore power or the battery first, and what voltage the built-in charger pushes into your bank. The factory defaults suit a lead-acid bank on shore power. If you have lithium, solar, or a generator, you'll want to change at least two of them.

The settings below come from the AIMS manual for the PICOGLF 3000W 12V with 30A/50A bypass. Check the label on your own unit, as switch functions can differ between models. Always turn the inverter off before moving a switch.

The five DIP switches

Switch Function Position 0 Position 1
SW1 Low battery trip point (AC priority) 10.0 VDC 10.5 VDC
SW1 Low battery trip point (battery priority) 10.5 VDC 11.5 VDC
SW2 AC input range 100-135 VAC 90-135 VAC (40 Hz+)
SW3 Power save override (battery priority only) Unit off charging Power saver on (3 sec)
SW4 Output frequency 50 Hz 60 Hz
SW5 Priority AC priority Battery priority

Figures are for 12V models.

SW1: low battery trip point

This sets the voltage where the inverter shuts down to protect the battery. In AC priority (SW5 at 0) you choose 10.0 or 10.5 V. In battery priority (SW5 at 1) the choices move up to 10.5 or 11.5 V, so a solar bank isn't drained deep every night. For lithium (LiFePO4), use the higher setting. A 12V LiFePO4 battery is nearly empty well before 10 V, and its own BMS may cut off first. Check your battery's low-voltage cutoff and set the inverter to trip above it.

SW2: AC input range

Position 0 only accepts 100-135 VAC, which protects sensitive electronics. Position 1 widens it to 90-135 VAC and down to 40 Hz. That stops the inverter from bouncing between generator and battery when a small or older generator sags under load. The trade-off is that your loads get the generator's rougher power. AIMS also says the generator should be rated at least 150% of the inverter's size.

SW3: power save

SW3 only matters in battery priority. Set to 1, the inverter sleeps and pulses every 3 seconds looking for a load over 50 watts. AIMS lists idle draw of about 21.7 W in this mode, against 55 W with power saver off. Set to 0 ("unit off charging"), it puts out no AC at all and only wakes up to charge when the battery is low. If you run a CPAP, a fridge with electronic controls, or anything under 50 W overnight, leave power saver off so the load doesn't drop out.

SW4: 50 or 60 Hz

In North America, leave it at 1 (60 Hz).

SW5: AC priority or battery priority

AC priority is the default. When shore power or a generator is connected, the unit charges the battery and passes shore power through to your loads, transferring to battery in about 10 ms if the power drops. That's the right setting for most RVs that plug in at campgrounds.

Battery priority runs your loads from the battery even with shore power connected. It only switches to AC to recharge when the battery reaches the low-voltage alarm point (10.5 V on 12V models), then goes back to battery once charging finishes. AIMS designed it for solar systems that use the grid as backup. It's useful if you have a large solar array and want to use your own power first.

Battery type selector

The rotary selector sets the charger's absorption ("boost") and float voltages. Position 0 turns the charger off.

Position Battery Boost (V) Float (V)
0 Charger off - -
1 Gel (USA) 14.0 13.7
2 AGM 1 14.1 13.4
3 AGM 2 14.6 13.7
4 Sealed lead acid / LiFePO4 14.4 13.6
5 Gel (Euro) 14.4 13.8
6 Open lead acid 14.8 13.3
7 Calcium 15.1 13.6
8 De-sulphation 15.5 for 4 hours, then off -
9 Not used / customized - -

Lithium owners: use position 4 (14.4 / 13.6 V). Never use 6, 7 or 8 on lithium. Position 8 is a high-voltage cycle for recovering sulfated lead-acid batteries, and AIMS marks it in red for a reason. The AIMS 12V 300Ah LiFePO4, 135Ah and 104Ah batteries all charge correctly on position 4.

Charge current dial

Next to the battery type selector is a small dial that limits the charger from 15% to 100% of its maximum. AIMS's rule of thumb is to keep bulk charging current to about 30% of your bank's amp-hour capacity unless the battery maker allows more. Turn the dial gently with a small jeweler's screwdriver. The charger sizes on PICOGLF models are:

Model Charger Price
1000W (PICOGLF10W12V120VR) 35A $681.00
1500W (PICOGLF15W12V120VR) 50A $814.00
2000W (PICOGLF20W12V120VR) 70A $940.60
2500W (PICOGLF25W12V120AL) 85A $653.00
3000W (PICOGLF30W12V120VR) 100A $987.53
4000W split phase, 240V charge input 115A $1,490.60

Prices on RV Parts Giant, November 12, 2026. For example, on a 100Ah lithium battery, turn a 3000W unit's 100A charger down to roughly a third of its maximum unless your battery's spec sheet allows more.

Common setups

  • RV on shore power with lead-acid or AGM: SW5 at 0 (AC priority), SW1 at 1 (10.5 V), SW2 at 0, SW4 at 1, selector on your battery type (2, 3 or 6).
  • RV with lithium: SW5 at 0, SW1 at 1, selector on 4, current dial sized to your bank.
  • Running off a generator: as above, plus SW2 at 1 so the unit accepts the generator's wider voltage and frequency.
  • Solar-first cabin or bus: SW5 at 1 (battery priority), SW1 at 1 (11.5 V), SW3 at 1 if you want power-saver sleep, selector on your battery type.

Other things on the DC end

  • Remote port: plug in the LCD remote (REMOTELF) or, on units with an LED port, the LED on/off remote (REMOTELFLED). Don't swap them: AIMS warns that plugging into the wrong port damages the inverter.
  • Battery temperature sensor: the PICGLFBATS sensor lets the charger lower its voltage when the battery is hot.
  • Auto generator start: a dry-contact relay (16A max) that can start a generator with an electric start when the battery gets low.
  • Bluetooth: add the BT-AIMS-PRO dongle to monitor from your phone.

FAQ

What's the difference between PICOGLF V and VR models? See AIMS PICOGLF Inverter Chargers Explained: V vs VR.

Why does my inverter tick and blink green? That's power saver mode searching for a load. Loads under 50 W won't wake it. Switch the front panel to "Power Saver Off" to keep full output on.

Why won't it pass generator power through? The unit waits 15 seconds after it sees good AC before it transfers. If the generator's voltage or frequency is outside the range set by SW2, it won't transfer at all. Try SW2 at 1.

Still unsure which unit to buy? Start with What size AIMS Power inverter does your RV need? or shop the full AIMS Power range.