Shurflo 4008 Wiring & Installation Guide

How to mount, plumb and wire a Shurflo Revolution 4008 RV water pump: fuse, wire gauge by run length, strainer, flexible hose and first start-up.

Shurflo Revolution 4008-101-A65 12V RV water pump

The Shurflo Revolution 4008-101-A65 is the most common replacement pump in RVs. It's a 12V, 3.0 GPM demand pump that turns on by itself when you open a tap. Most owners can install one in under an hour. Here's how to wire and plumb it properly the first time.

Safety first: turn off the pump switch, disconnect shore power, and pull the pump fuse before you start. Work with the fresh tank valve closed, or the tank drained.

What you need

  • The pump, plus the fittings that came with it (or adapters to match your lines)
  • An inlet strainer, if your old pump didn't have one
  • Butt connectors or heat-shrink connectors, a crimper, and a multimeter
  • A screwdriver or nut driver for the mounting screws

Step 1: remove the old pump

Take a photo of the wiring and plumbing. Disconnect the two wires and both water lines, with a towel ready for drips, then unscrew the mount. If you can't reach the pump, see replacing an RV water pump with no access panel.

Step 2: mount it

  • Mount it on a solid surface. A flimsy floor acts like a speaker.
  • Snug the screws only until the rubber feet start to compress. Over-tightened feet transmit vibration and noise.
  • Keep the pump in a dry spot, and as close to the tank as practical. A short suction line primes faster.

Step 3: plumb it

  • Inlet: fit a strainer on the tank side to protect the valves from debris.
  • Flexible hose: use about 12–18 in. of flexible hose on both the inlet and outlet. Rigid pipe straight into the pump head carries noise through the whole rig.
  • Direction: follow the flow arrows on the pump head.
  • Use thread sealant on threaded fittings, not too much, and don't overtighten plastic ports.

Step 4: wire it

  • Polarity: pump red to the switched positive (+), pump black to negative (−).
  • Fuse: fuse the positive wire near the power source, using the rating on the pump label. The 4008's max draw is about 7.5 A.
  • Connections: use crimped, heat-shrink butt connectors. Twisted wires and tape loosen with road vibration, and a voltage drop makes the pump run weak.

Wire size by run length (one way, from the fuse panel to the pump)

One-way run Minimum wire
Up to 10 ft 14 AWG
10–15 ft 12 AWG
15–25 ft 10 AWG

The sizes above aim for about 3% voltage drop at 7.5 A. If your RV's existing wire is smaller and the pump seems weak, measure the voltage at the pump while it runs. Below about 12 V under load, the wire is too small or a connection is bad.

Step 5: prime and test

  1. Open the fresh tank valve, and make sure the winterizing bypass is set to draw from the tank.
  2. Open a cold tap, then turn the pump on. It may run for a bit while it pushes out air.
  3. Once water flows steadily, open each hot and cold tap in turn to purge air, then close them all.
  4. The pump should shut off and stay off. If it restarts every few minutes, look for a leak. If it never shuts off, see Shurflo pressure switch adjustment and troubleshooting.

Optional: add an accumulator

An inline accumulator on the outlet side smooths out pulsing at low flow and cuts short-cycling. The Shurflo 182-200 is pre-charged to 30 PSI and works with systems from 20 to 125 PSI.

Replacing a 2088?

The 4008 is the usual upgrade for older Shurflo 2088 pumps. Flow is similar (3.0 GPM), and the shutoff pressure is often higher (55 PSI vs about 45 PSI on many 2088s). Check the port style and mounting holes, which may need new fittings, and confirm your fuse and wire suit the 4008.

FAQ

Can I wire the pump straight to the battery? Not without a fuse and a switch. Use the RV's existing pump circuit, or add a fused, switched circuit.

Why does my new pump hum loudly? Usually it's compressed mounting feet, a hollow mounting floor, or rigid plumbing at the pump. See the mounting and plumbing steps above.

3.0 or 4.0 GPM? See Shurflo 4008 vs 4048.

More help: How to replace an RV water pump · 12V RV water systems explained