Shurflo Pressure Switch Adjustment (4008, 4048, Aqua King)

When to adjust a Shurflo pump's pressure switch and when not to, how to do it safely, and what to check first if the pump cycles or won't shut off.

Shurflo Revolution 4008-101-A65 12V RV water pump

Short answer: most Shurflo pumps that cycle or won't shut off have a leak, air in the line, or a clogged strainer, not a mis-set switch. Rule those out first. Adjust the switch only in small steps, and never above the pump's rated shutoff pressure (55 PSI on the 4008 and 4048).

How the switch works

A Shurflo demand pump runs until the water line reaches its shutoff pressure, then the pressure switch cuts power. When you open a tap, pressure drops and the switch turns the pump back on. If the line can't hold pressure, or the pump can't build pressure, the switch never gets the signal to stop.

Check these first

  1. Leaks on the pressure side. Close every tap. If the pump kicks on briefly every few minutes, water is escaping somewhere: a dripping faucet, the toilet valve, the water heater relief valve or a loose fitting. Walk the lines with a flashlight.
  2. Empty tank or air leak on the inlet. If the pump runs and never shuts off, check the tank level, then the inlet fittings and the strainer bowl seal. An air leak on the suction side stops the pump from building pressure.
  3. Clogged inlet strainer. Clean the strainer screen. A starved pump runs and runs.
  4. Winterizing bypass left open. If a winterizing valve is still set to draw from the antifreeze hose, the pump sucks air.
  5. Low battery voltage. A weak battery can mean the pump can't reach shutoff pressure. Measure the voltage at the pump while it runs.

For the full troubleshooting tree, see RV water pump cycling on and off and RV water system troubleshooting.

Pulsing at low flow is normal

At a trickle, a pressure-switch pump turns on and off quickly. That's how it's designed, not a switch fault. The fix is an accumulator tank, not an adjustment. The Shurflo 182-200 comes pre-charged to 30 PSI. See Why is my RV water pump pulsing when a tap is open?

Adjusting the switch

Only adjust if the pump is otherwise healthy, there are no leaks, it primes fine, and it shuts off a little early or a little late.

  1. Turn off the pump at its switch or breaker.
  2. Find the adjustment screw on the pressure switch housing. On many Shurflo switches it sits in the center of the switch cap.
  3. Turn the screw in small steps, about an eighth of a turn at a time. Clockwise usually raises shutoff pressure, and counter-clockwise lowers it.
  4. Turn the pump on, open and close a tap, and check that it shuts off cleanly. Use a pressure gauge on a faucet or the city-water inlet if you have one.
  5. Never set it above the pump's rated shutoff pressure. Higher pressure strains fittings and the motor, and the pump may never reach shutoff.

When to replace the switch or pump

If the switch is cracked or leaking, or the pump still won't shut off with no leaks and good voltage, replace the switch with the correct Shurflo part for your model, or replace the pump. A Revolution 4008 is the usual replacement for most RVs. See how to replace an RV water pump.

FAQ

What should a Shurflo RV pump shut off at? The 4008 and 4048 are rated at 55 PSI. Check the label on yours, since older Shurflo models were often lower (around 45 PSI).

Does an accumulator need its own setting? Yes. Set the air pre-charge a little below the pump's turn-on pressure, with the system unpressurized. The 182-200 comes at 30 PSI.

Have a SEAFLO instead? See SEAFLO pressure switch adjustment.