A Renogy DC-DC charger only needs four or five connections, but the order you make them in, where the fuses go and how you handle the negatives decide whether it works on the first try. Renogy's manuals are also different for each model. The 20A/40A Gen 2 has separate input and output negatives, the DCC30S/DCC50S has one common negative, and the IP67 50A uses fly leads and a busbar.
Below are text wiring diagrams for each charger, plus connection order, fuses, grounding, smart alternators and trailers, all from Renogy's current manuals. If you still need to pick a size, start with which size Renogy DC-DC charger you need, then come back here.
The short answer
- Three runs: starter battery positive to the charger input, charger output to the house battery positive, and the negatives. MPPT models add a solar input.
- Fuse both positive runs, with each fuse as close to its battery as you can get it. On the DCC30S/DCC50S, Renogy says to put the starter-side fuse no more than about 20 cm from the starter battery positive.
- Connect the battery before solar, and cover the panels while you wire them.
- Only smart alternators need the IGN wire on the Gen 2 and DCC30S/DCC50S. The IP67 50A has no IGN wire. You adjust its cut-in voltage in the app instead.
- Don't fit the temperature sensor to a lithium battery that has a BMS. All three manuals say this.
Terminal layout and wiring diagram by model
Fuse sizes below come from each model's own manual.
12V 20A/40A DC-DC Gen 2 (RBC20D1U / RBC40D1U)
| Charger terminal | Connects to | Fuse |
|---|---|---|
| Positive Input | Starter battery + | ANL, 40A (20A model) / 80A (40A model) |
| Negative Input | Starter battery − | None |
| Positive Output | House (auxiliary) battery + | ANL, 30A (20A model) / 40A (40A model) |
| Negative Output | House battery − | None |
| IGN Signal Wire port | Ignition signal, for smart alternators only (3 m wire included) | Check your vehicle's wiring |
| BTS port | Temperature sensor at the battery (lead-acid only) | None |
| RS485 port | BT-2 Bluetooth module (optional) | None |
Renogy's Gen 2 manual lists 8 AWG (20A) or 6 AWG (40A) for the input and 10 AWG or 8 AWG for the output. It also recommends keeping cables under 10 m (32.8 ft). The Gen 2 has no solar input.
DCC30S / DCC50S with MPPT (RBC30D1S / RBC50D1S)
| Charger terminal | Connects to | Fuse |
|---|---|---|
| ALT+ | Starter battery + | 50A (DCC30S) / 80A (DCC50S), within about 20 cm of the battery |
| OUT+ (BATT) | House battery + | 40A (DCC30S) / 60A (DCC50S) |
| PV+ | Solar array + | Solar fuse = array Isc × 1.56 |
| NEG− (common) | House battery −. The solar negative and starter battery negative also tie to the house battery negative. | None |
| IGN | Vehicle ignition, for smart alternators only | Check your vehicle's wiring |
| BTS / BVS | Temperature sensor and voltage sensor at the house battery | None |
Solar limits from the manual: the array working voltage must be at least 15V. The ceiling is 30V and 400W on the DCC30S, and 50V and 660W on the DCC50S. Renogy's own Go Far RV Solution guide shows an 80A fuse on the DCC50S output, while the charger manual lists 60A. Use the manual's 60A figure.
12V/24V IP67 50A with MPPT (RBC2125DS-21W)
| Charger lead | Connects to | Fuse |
|---|---|---|
| Positive Starter Battery Cable (red) | Starter battery + | ANL 70A |
| Positive Auxiliary Battery Cable (brown) | House battery + | ANL 60A |
| Positive Solar Cable (yellow) | Solar array + | Solar fuse = Isc × 1.56 |
| Negative Common Cable (black) | Negative busbar (60A to 100A), along with the starter, house and solar negatives | None |
| Temperature sensor cable | Sensor near the battery (not on BMS lithium) | None |
| CAN ports | RV-C bus or Renogy CAN devices (optional) | None |
On the IP67 50A, keep the solar array at or below 50V open-circuit, 720W and 48A short-circuit current. The newer IP67 50A Pro is a different model, so follow its own manual.
Connection order, step by step
Renogy says to follow the sequence in each manual. They differ slightly, but they share this pattern:
- Disconnect and prepare. Wear insulating gloves and use insulated tools. Cover any solar panels.
- Negatives first. The DCC30S/DCC50S manual says not to connect a positive terminal first. Its first step is the NEG− terminal. The IP67 manual starts with the negative common cable to the busbar.
- House battery output. Connect the charger output to the fuse, then the fuse to the house battery positive. The Gen 2 manual does this first.
- Solar input (MPPT models). Connect solar only after a battery is connected. The IP67 manual says this outright.
- Starter battery input. Run the charger input to a fuse near the starter battery. Renogy's trailer install write-up makes the starter battery positive the very last connection, after everything downstream is secure.
- IGN wire (smart alternators only), then the temperature sensor and any voltage sensor or Bluetooth module.
- Tug-test every lug and set the battery type with the button, knob or app before you drive. Renogy notes that damage from a wrong battery-type setting isn't covered by the warranty.
Ground and negative practices
- Gen 2: the input and output have separate negative terminals. The manual runs one negative cable to the starter battery and another to the house battery.
- DCC30S/DCC50S: there is one NEG− terminal. The starter battery and solar negatives must share the house battery's negative.
- IP67 50A: Renogy recommends a negative busbar with all negatives landed on it. Our red and black busbar set works for this.
- Size each negative cable the same as its positive. If you use a shunt-based monitor, all of these negatives belong on the load side of the shunt.
Smart alternator setup
Check your alternator type first. Renogy's test is to start the engine with fans, radio and lights off, let it run 5 to 10 minutes, then measure at the starter battery. Around 14.4V usually means a traditional alternator. Around 12.5V to 13.5V usually means a smart alternator.
| Model | Traditional alternator | Smart alternator |
|---|---|---|
| 20A/40A Gen 2 | No IGN. Starts at 13.2V for 15 s, stops at 12.7V. | IGN required. Starts at 12V for 15 s, stops at 11V per the Gen 2 manual (Renogy's quick guide says 11.5V). |
| DCC30S/DCC50S | No IGN. Starts at 13.2V for 15 s, stops at 12.7V. | IGN required. Starts at 12.0V for 15 s, stops at 11.5V. |
| IP67 50A | No IGN wire. Default cut-in is 13.2V and cut-out is 12.7V (12V system). If the alternator output is low, you can change the cut-in in the DC Home app. | |
Renogy's Gen 2 manual and its quick guide give different smart-alternator stop voltages (11V and 11.5V). If you can set it, use the higher 11.5V figure so the starter battery keeps more reserve.
Use an ignition-switched source for the IGN wire. Renogy's D+ wiring guide suggests the alternator's ignition circuit or an accessory fuse in the engine-bay fuse block. Use a multimeter to find a 12V signal that appears only with the key on. Before you lower any cut-in voltage on the IP67, check with your vehicle maker, because Renogy warns that a cut-in set too low can run the starter battery down.
Trailer-specific notes
- Mount the charger in the trailer, near the house battery. The DCC30S/DCC50S manual asks for it as close to the battery as possible and strongly recommends staying within 1.5 m.
- Don't push charge current through the 7-pin. Renogy's own team tried it and found the pin limited the current. They moved the charging run to 4 AWG cable with an Anderson connector.
- Size the long tow-vehicle run from the manual's table. On the DCC30S/DCC50S, cable length means positive plus negative added together. Run a matching negative back to the starter battery.
- Fuse at the tow-vehicle battery, and consider a switch on the bumper Anderson feed. One Renogy customer added one so the connector isn't live when they're not towing.
What you need
- A charger: 12V 20A/40A DC-DC Gen 2 for alternator-only charging, DCC30S/DCC50S with MPPT to add solar, or the 12V/24V IP67 50A for wet locations, 24V systems or RV-C.
- Two ANL fuses and holders sized from the tables above, plus a solar fuse on MPPT models.
- Copper cable in the manual's gauge, lugs and a crimper.
- Optional: a 500A battery monitor with shunt to confirm charge current. Browse every model in our Renogy DC-DC chargers collection.
FAQ
Do I need the IGN or D+ wire?
On the Gen 2 and DCC30S/DCC50S, only if you have a smart alternator. A traditional alternator runs on voltage sensing alone. The IP67 50A has no IGN wire.
Can I ground the charger to the chassis instead of the battery?
Renogy's manuals show dedicated negative cables to the battery negatives or a busbar. Follow that, especially on trailers, where the chassis path through the hitch is poor.
Why does my charger show no output?
Check that the starter battery reaches the cut-in voltage with the engine running. On a smart alternator, check that the IGN wire has 12V with the key on. Then confirm both fuses are intact.
Can I use the temperature sensor with my lithium battery?
Not if the lithium battery has a BMS. Renogy's manuals say the sensor is for batteries without one, and the Gen 2 sensor port is for lead-acid only.