Victron Off-Grid System Design for RVs: Sizing Every Part

Size a Victron off-grid RV system in six steps: daily load, battery bank, solar array, MPPT, inverter/charger and monitoring, with two worked examples.

Victron 12V travel trailer power kit with MultiPlus-II, MPPT, Orion XS, Lynx and Cerbo GX

Designing a Victron off-grid system is mostly arithmetic. Work out how much energy you use in a day, then size the battery to store it, the solar to replace it and the inverter to deliver it. This guide walks through each step with the numbers, then shows two finished designs: a weekend van and a full-time travel trailer.

Once the parts are chosen, our build guide, How to Build a Victron Off-Grid Power System for Your Camper, covers installation.

Step 1: Add up your daily load

List everything that runs off the battery, how many watts it draws and how many hours a day it runs. Multiply to get watt-hours (Wh) per day.

Load Watts Hours/day Wh/day
12V compressor fridge 45 (average while running) 10 450
LED lights 20 5 100
Water pump 60 0.5 30
Roof fan 30 6 180
Laptop and phones 60 4 240
Microwave 1,200 0.25 300
Inverter standby 15 24 360
Total 1,660

Two things catch people out. Inverter idle draw adds up over 24 hours, so turn the inverter off or use its search mode when you don't need AC. And air conditioning changes everything: a 13,500 BTU roof A/C can use 1,000–1,500 Wh every hour it runs, which is why most off-grid systems are designed without it. If you only need to cool the bedroom, a low-draw battery camping AC is a far smaller load; see battery camping AC vs a regular portable AC.

Step 2: Choose the system voltage

  • 12V suits vans and most trailers with inverters up to about 3,000VA. Almost every RV appliance is 12V, so there's no converter needed.
  • 24V makes sense for larger inverters, long cable runs or big solar arrays. It halves the current, so cables and fuses get smaller. You'll need a 24-to-12V DC-DC converter for the RV's 12V loads.

Victron makes most parts in both versions, so pick the voltage first and buy everything to match.

Step 3: Size the battery bank

Battery Wh = daily Wh × days of autonomy ÷ usable depth of discharge

Days of autonomy is how long you want to last with no sun and no driving: 1 day for a weekend system, 2–3 for full-timers. Lithium (LiFePO4) can be used to about 80–90% depth of discharge. Lead-acid should stay above 50%.

For the 1,660 Wh/day example with 2 days of autonomy on lithium:
1,660 × 2 ÷ 0.85 ≈ 3,900 Wh, which at 12.8V is about 305Ah. Two 200Ah 12.8V batteries (5,120 Wh) give comfortable headroom.

Battery choice: Victron lithium batteries, and our Smart vs NG vs SuperPack guide explains the differences. Victron Smart and NG lithium batteries need a separate Victron BMS (an NG battery needs an NG BMS, such as the VE.Bus BMS NG or Lynx Smart BMS NG); the SuperPack has its own built in. See battery management and protection.

Step 4: Size the solar array and MPPT

Solar watts = daily Wh ÷ peak sun hours ÷ 0.75

The 0.75 covers panel heat, dust, shading and charging losses. Peak sun hours are roughly 5–6 in the Southwest summer, 3–4 for most of the US in spring and fall, and 2 or less in a northern winter. Design for the season you actually camp in.

For 1,660 Wh/day at 4 peak sun hours: 1,660 ÷ 4 ÷ 0.75 ≈ 550W of solar. On a trailer roof that's three or four panels.

Then size the MPPT controller. In Victron's model names the first number is the maximum PV open-circuit voltage and the second is the maximum charge current, so check both:

  • Current: solar watts ÷ battery voltage. 550W ÷ 12V ≈ 46A, so a 100/50 or a 150/45 at the edge, or a 150/60 or 150/70 for room to add panels.
  • Voltage: the panel string's open-circuit voltage (Voc), increased by about 10–15% for cold mornings, must stay below the controller's first number (100V or 150V).

Victron's online MPPT calculator checks a specific panel and controller combination. Options: SmartSolar MPPT 100/30 and 100/50, 150/35 and 150/45, and larger VE.Can models up to 250/100. More detail in our SmartSolar MPPT review.

Step 5: Size the inverter/charger

Size the inverter for the largest set of AC loads that run at the same time, not the daily total. A microwave (about 1,200–1,500W from the wall) plus a coffee maker needs more than 2,000W. Victron rates the MultiPlus in VA, and the continuous watt rating is lower than the VA figure, so check the datasheet: a 3000VA MultiPlus-II is rated for about 2,400W continuous.

The charger side matters too: it's how fast shore power or a generator refills the battery. See MultiPlus vs MultiPlus-II vs Quattro and the full range of Victron inverter/chargers.

Step 6: Alternator charging, monitoring and protection

  • Alternator: a DC-DC charger like the Orion XS protects the vehicle alternator and charges lithium properly while you drive. It's adjustable up to 50A, so an hour of driving puts back up to about 600–700 Wh. Install guide: wiring a Victron Orion.
  • Monitoring: a SmartShunt gives an accurate state of charge, and a Cerbo GX ties every device together, adds remote monitoring through VRM and lets you turn on DVCC so all chargers share one set of limits.
  • Distribution and fusing: a Lynx busbar system with a Class T fuse at the battery. See Lynx and DC distribution.

Two worked designs

Weekend van Full-time travel trailer
Daily load ~800 Wh ~1,700 Wh
System voltage 12V 12V (24V if you plan to grow past 3,000VA)
Battery 200Ah 12.8V lithium (2,560 Wh) 2 × 200Ah 12.8V lithium (5,120 Wh)
Solar 300–400W 600–800W
MPPT SmartSolar 100/30 SmartSolar 150/70
Inverter/charger MultiPlus 12/2000 MultiPlus-II 12/3000 2x120V
Alternator charging Orion XS 50A Orion XS 50A (if towing vehicle wiring allows)
Monitoring SmartShunt SmartShunt + Cerbo GX + GX Touch 50
Matching kit 12V Van & Small Camper Power Kit 12V Travel Trailer Power Kit

Both kits leave out batteries, solar panels and cable, so you can size the bank from Step 3. For a 24V build, see the 24V Off-Grid Trailer Power Kit. All options are in Victron power kits and complete systems.

Design checklist

  1. Daily load in Wh, including inverter standby.
  2. System voltage chosen, every part bought to match.
  3. Battery sized for daily load × days of autonomy, with the right BMS.
  4. Solar sized for the season you camp in.
  5. MPPT checked for both current and cold-weather Voc.
  6. Inverter sized for simultaneous AC loads.
  7. DC-DC charger for driving days.
  8. Battery monitor, GX device and fusing.
  9. Cables and fuses sized for the current. Our MultiPlus install guide covers inverter cable and fuse sizes.